Skip to content
bottling-plant-800x450-3
Food & Drink

Site energy reduction plan

Client: Charles Wells
Services:
Energy Audit/Survey Energy Improvement Projects
Sector:
Food & Drink

Services provided

  • Site energy reduction plan
  • Business case preparation
  • Brief for survey of steam traps and distribution network
  • New metering strategy
  • Plant condition survey
  • Building survey and improvement identification
  • Nitrogen supply analysis and strategy development

Benefits achieved

>£400k pa potential savings identified

Summary

The site had an estimated annual energy expenditure of c£3.5 million and energy usage or efficiency had not been a priority JRP Solutions were engaged to support the energy management activities of the site’s engineering team by providing focussed and specialist resources, since which time JRP Solutions have:

  • Developed an initial Site Energy Reduction Plan containing around 30 prioritised energy reduction opportunities with a potential cost reduction of over £400,000 per year
  • Worked with the Wells & Young’s engineering team to develop business cases and plans for financial approval for boiler improvements
  • Developed the brief for a comprehensive survey of the steam traps and steam distribution network
  • Carried out a review of the sub-metering system, and helped to develop a new metering strategy with the aim of establishing budget costs that were added to the following year’s capital plan
  • Completed a plant condition survey of the CO2 recovery plant, and specified and sourced CO2 metering
  • Carried out a detailed survey of the Hop Store and identified opportunities to reduce costs and improve the storage facility.
  • Analysed the nitrogen meter data and identified that a large proportion of the nitrogen demand was not being metered

Results

Savings of over £400k were identified through the site energy reduction plan and further energy and cost savings were made through boiler improvements Improved metering and data analysis has enabled more efficient energy and nitrogen control.

| The site had an estimated annual energy expenditure of c£3.5 million and energy usage or efficiency had not been a priority JRP Solutions were engaged to support the energy management activities of the site’s engineering team. | full_html

For more information, request the full case study below.

REQUEST THE FULL CASE STUDY

Enter your details to get access to the full case study

We are offering downloads of our full case studies to energy and sustainability professionals involved in any stage of their organisation’s energy or sustainability journey. If you would like to receive a copy of this case study, simply request your download here.

"*" indicates required fields

Enjoy exclusive emails and updates from JRP. You can, of course, opt out of these communications at any time! See our Privacy Policy for more info.